- Standard: SFS-1265-3:2014
- Diameter range, mm: 9,3 - 15,2
- Tensile strength, MPa: 1860
Instruction for unwinding reinforcing strands (ropes)
Coils of reinforcing strands (ropes) are marked with a paper self-adhesive label with the image “arrow” to indicate the direction of unwinding of the strand in the following order (Figure 1):
– On the reinforcing strands (ropes) of the right twist, the arrow is directed inside the coil;
– On reinforcing strands (ropes) of the left twist, the arrow points outward of the coil.


Figure 1 Direction of unwinding of a strand (rope)
To avoid tangling of strands (ropes) during their processing, it is necessary to unwind a reinforcing strand (rope) depending on the direction of stranding (rope) in the direction indicated by the arrow (Figure 1).
TABLE 1. The dimensions and properties of the strands according to SFS-1265-3:2014
Nominal values | Calculated values | |||||||
Strand diameter d, mm | Tensile strength Rm, N/mm2 | Cross-section area Sn, mm 2 | Mass of one meter length M, g/m | Allowable deviation from the mass of one meter length, % | Characteristic value off maximum load Fm, kN
| Characteristic value of 0.1% of maximum permissible load Fp 0.1s, kN
| Normative limit value of maximum load Fm, max, kN m
| The minimum value of the total elongation at maximum load, Agt, with Lo ≥ 500 mm, %
|
7-wire (with a round and periodic profile of external wires) | ||||||||
9,3 | 1860 | 52 | 406,1 | ± 2,0 | 96,7 | 85,1 | 111 | 3,5 |
9,6 | 1860 | 55 | 429,6 | ± 2,0 | 102,0 | 89,8 | 117 | 3,5 |
11,0 | 1860 | 70 | 546,7 | ± 2,0 | 130,0 | 114,0 | 150 | 3,5 |
11,3 | 1860 | 75 | 585,8 | ± 2,0 | 140,0 | 123,0 | 161 | 3,5 |
12,5 | 1860 | 93 | 726,3 | ± 2,0 | 173,0 | 152,0 | 199 | 3,5 |
12,9 | 1860 | 100 | 781,0 | ± 2,0 | 186,0 | 164,0 | 214 | 3,5 |
13,0 | 1860 | 102 | 796,6 | ± 2,0 | 190,0 | 167,0 | 219 | 3,5 |
15,2 | 1860 | 139 | 1086,0 | ± 2,0 | 259,0 | 228,0 | 298 | 3,5 |
Note a. The elastic modulus (E) can be taken as 195 GPa (kN / mm2) +/- 15%. Note b. The nominal linear density (mass of one meter of length) of the product is calculated from the cross-sectional area and density of 7.81 kg / dm3. Note c. The characteristic value of 0.1% of the maximum allowable load is calculated for all diameters as 88% of the specified characteristic value of the maximum load. Relaxation after 1000 hours is not more than 2.5% at an initial voltage of 70% Rm. Special properties according to the additional requirements as per SFS-1265-3:2014. |
The strands are delivered in coils: - inner diameter: 750 mm, 800 mm, 900 mm; - outer diameter: max. 1600 mm; - width: 750 mm, 630 mm; The maximum weight of the coils is 4 tons. 7-wire strands are delivered with in-line styling.
- Type of winding:Strands
- Dimensions, mm, d*D*h:750 mm, 630 mm;
- Weight kg:4 t
- Diameter range, mm:750 mm - 1600 mm