Czech Construction Technical Opinion STO No. 070-066457 approval of conformity for products “Low relaxation reinforcing strands for reinforcing prestressed concrete Y1860S7”
  • Standard: STO № 070-066457
  • Diameter range, mm: 9,3-15,7
  • Tensile strength, MPa: 1860
Instructions
Specifications
Packaging
Calculator
Contacts

Instruction for unwinding reinforcing strands (ropes)

Coils of reinforcing strands (ropes) are marked with a paper self-adhesive label with the image “arrow” to indicate the direction of unwinding of the strand in the following order (Figure 1):

– On the reinforcing strands (ropes) of the right twist, the arrow is directed inside the coil;

– On reinforcing strands (ropes) of the left twist, the arrow points outward of the coil.

Strand (rope) of the right twist
Strand (rope) of the left twist

Figure 1 Direction of unwinding of a strand (rope)

To avoid tangling of strands (ropes) during their processing, it is necessary to unwind a reinforcing strand (rope) depending on the direction of stranding (rope) in the direction indicated by the arrow (Figure 1).

Dimensions and properties of strands according to STO No. 070-066457

Nominal values a

Estimated values

Strand diameter

d,

мм

tensile strength
Rm,
Н/мм2

Cross-sectional area

Sn,

мм 2

Weight of 1

meter length b

 М,

г/м

Permissible

deviation of

mass of 1 meter of length, %

Characteristic value of maximum load

Fm,

кН

Characteristic value 0.1% of maximum permissible load Fp 0,1с,

кН

Standard maximum load limit value Fm,max,  кН

Minimum value of full elongation at maximum load, Аgt, с Lo ≥ 500 мм, %

семи-дротяні пасма

9,3

186052406,1± 2,096,785,11113,5
9,6186055429,6± 2,0102,089,8117

3,5

11,0186070546,7± 2,0130,0114,0150

3,5

11,3186075585,8± 2,0140,0123,0161

3,5

12,5186093726,3± 2,0173,0152,0199

3,5

12,91860100781,0± 2,0186,0164,0214

3,5

13,01860102796,6± 2,0190,0167,0219

3,5

15,218601391086,0± 2,0259,0228,0298

3,5

15,318601401093± 2,0260229299

3,5

15,718601501172± 2,0279246321

3,5

Note a. The modulus of elasticity (E) may be taken as 195 GPa (kN/mm2).
Note b. The nominal linear density (mass per meter length) of the product is calculated from the cross-sectional area and the density of steel 7.81 kg/dm3.
Note c. The characteristic value of 0.1% of the maximum allowable load is calculated for all diameters as 88% of the specified characteristic value of the maximum load.
Relaxation after 1000 hours with an initial load of 70% of Fmа not more than 2.5% and not more than 4.5% for F0=80% Fmа
Special properties in accordance with additional requirements according to STO No. 070-066457.

Strands

The strands are delivered in coils: - inner diameter: 750 mm, 800 mm, 900 mm; - outer diameter: max. 1600 mm; - width: 750 mm, 630 mm; The maximum weight of the coils is 4 tons. 7-wire strands are delivered with in-line styling.

  • Type of winding:Strands
  • Dimensions, mm, d*D*h:750 mm, 630 mm;
  • Weight kg:4 t
  • Diameter range, mm:750 mm - 1600 mm

Calculator