- Standard: FprEN 10138-3:2009
- Diameter range, mm: 6,5÷15,7
- Tensile strength, MPa: 1770, 1860
Instruction for unwinding reinforcing strands (ropes)
Coils of reinforcing strands (ropes) are marked with a paper self-adhesive label with the image “arrow” to indicate the direction of unwinding of the strand in the following order (Figure 1):
– On the reinforcing strands (ropes) of the right twist, the arrow is directed inside the coil;
– On reinforcing strands (ropes) of the left twist, the arrow points outward of the coil.


Figure 1 Direction of unwinding of a strand (rope)
To avoid tangling of strands (ropes) during their processing, it is necessary to unwind a reinforcing strand (rope) depending on the direction of stranding (rope) in the direction indicated by the arrow (Figure 1).
Strands according to FprEN 10138-3: 2009 “Tensile reinforcement – Part 3: Strand” – 3- and 7-wire designs of round or periodic cross-section wire;
The dimensions and properties of the strands according to FprEN 10138-3: 2009.
Nominal values | Calculated values | |||||||
Strand diameter d, mm | Tensile strength Rm, N/mm2 | Cross-sectional areab Sn, mm 2 | Mass of one meter length M, g/m | Allowable mass deviation of one meter length, %
| Characteristic value of maximum load Fm, kN
| The characteristic value of 0.1% of the maximum permissible load Fp 0.1s, kN
| Normative limit value maximum load Fm, max, kN
| Minimum value of total elongation at maximum load, Agt, with Lo ≥ 500 mm,% |
3-strands | ||||||||
6,5 | 1860 | 21,2 | 165,6 | ± 2,0 | 39,4 | 34,7 | 45,3 | 3,5 |
6,9 | 1860 | 23,4 | 182,8 | ± 2,0 | 43,5 | 38,3 | 50 | 3,5 |
8,6 | 1860 | 37,4 | 292,1 | ± 2,0 | 69,6 | 61,2 | 80 | 3,5 |
7-strands | ||||||||
6,9 | 1770 | 29,0 | 226,5 | ±2,0 | 51,3 | 45,1 | 59 | 3,5 |
6,9 | 1860 | 29 | 226,5 | ± 2,0 | 53,9 | 47,4 | 62 | 3,5 |
8,0 | 1860 | 38,0 | 296,8 | ± 2,0 | 70,7 | 62,2 | 81,3 | 3,5 |
9,0 | 1770 | 50 | 390,5 | ± 2,0 | 88,5 | 77,9 | 102 | 3,5 |
9,0 | 1860 | 50 | 390,5 | ± 2,0 | 93,0 | 81,8 | 107 | 3,5 |
9,3 | 1770 | 52,0 | 406,1 | ± 2,0 | 92,0 | 81,0 | 106 | 3,5 |
9,3 | 1860 | 52 | 406,1 | ± 2,0 | 96,7 | 85,1 | 111 | 3,5 |
9,6 | 1770 | 55 | 429,6 | ± 2,0 | 97,4 | 85,7 | 112 | 3,5 |
9,6 | 1860 | 55 | 429,6 | ± 2,0 | 102,0 | 89,8 | 117 | 3,5 |
11,0 | 1770 | 70 | 546,7 | ± 2,0 | 124,0 | 109,0 | 143 | 3,5 |
11,0 | 1860 | 70 | 546,7 | ± 2,0 | 130,0 | 114,0 | 150 | 3,5 |
11,3 | 1860 | 75,0 | 585,8 | ± 2,0 | 140 | 123 | 161 | 3,5 |
12,5 | 1770 | 93 | 726,3 | ± 2,0 | 165,0 | 145,0 | 190 | 3,5 |
12,5 | 1860 | 93 | 726,3 | ± 2,0 | 173,0 | 152,0 | 199 | 3,5 |
12,9 | 1770 | 100 | 781,0 | ± 2,0 | 177 | 156 | 204 | 3,5 |
12,9 | 1860 | 100 | 781,0 | ± 2,0 | 186,0 | 164,0 | 214 | 3,5 |
13,0 | 1860 | 102 | 796,6 | ± 2,0 | 190,0 | 167,0 | 219 | 3,5 |
15,2 | 1770 | 139 | 1086,0 | ± 2,0 | 246,0 | 216,0 | 283 | 3,5 |
15,2 | 1860 | 139 | 1086,0 | ± 2,0 | 259,0 | 228,0 | 298 | 3,5 |
15,3 | 1770 | 140 | 1093 | ± 2,0 | 248 | 218 | 285 | 3,5 |
15,3 | 1860 | 140 | 1093 | ± 2,0 | 260 | 229 | 299 | 3,5 |
15,7 | 1770 | 150 | 1172 | ± 2,0 | 266 | 234 | 306 | 3,5 |
15,7 | 1860 | 150 | 1172 | ± 2,0 | 279 | 246 | 321 | 3,5 |
Note a. The elastic modulus (E) can be taken as 195 GPa (kN / mm2).Note b. The nominal linear density (mass of one meter of length) of the product is calculated from the cross-sectional area and density of 7.81 kg / dm3. Note c. The characteristic value of 0.1% of the maximum allowable load is calculated for all diameters as 88% of the specified characteristic value of the maximum load. Relaxation after 1000 hours no more than 2.5% Special properties in accordance with the additional requirements of FprEN 10138-3: 2009. |
The strands are delivered in coils: - inner diameter: 750 mm, 800 mm, 900 mm; - outer diameter: max. 1600 mm; - width: 750 mm, 630 mm; The maximum weight of the coils is 4 tons. 7-wire strands are delivered with in-line styling.
- Type of winding:Strands
- Dimensions, mm, d*D*h:750 mm, 630 mm;
- Weight kg:4 t
- Diameter range, mm:750 mm - 1600 mm